I. Daily maintenance and care contents for drilling pumps:
1. Stop the pump and check the oil level. If the oil level is too low, it should be increased to the required height.
2. Check if the pressure gauge reading of the lubricating oil pump is normal. If the pressure is too low, the cause should be checked in time. 3: Check whether the air intake package is working properly.
When the cooling and lubricating fluid in the water tank of the spray pump is insufficient, it should be filled up. If it deteriorates, it should be replaced.
5. Inspect the front cavity of the frame. If there is a large amount of drilling fluid or oil sediment, it should be cleaned up.
Check if the cylinder head is loose every 4 hours and apply grease to the threads during installation.
7. Observe whether there are any puncturing or leaking phenomena on the piston and cylinder liner. Replace them if the situation is severe.
Loosen the piston rod clamp once a day. After rotating the piston rod by a quarter of a turn, tighten the clamp.
9. Check if the valve cover is loose every 4 hours. When installing, apply grease to the threads.
10. Check whether the safety valve is reliable.
11. When the pump is stopped, check whether the pre-charge pressure of the discharged air package meets the operating conditions.
12. Observe the alarm hole. If drilling fluid is discharged, the corresponding sealing ring should be replaced in time (there are four sealing rings for each liquid cylinder).
13. Disassemble the cylinder head and valve cover, remove the dirt, and apply extreme pressure (composite) lithium-based grease.
14. Check the inner sleeve of the valve guide. If the wear exceeds the requirements, it needs to be replaced.
15. Inspect the suction and discharge valve bodies, valve seats, valve rubber sheets and valve springs. Any damaged ones need to be replaced.
16. Check whether the piston lock nut is corroded or damaged. If it is damaged, it needs to be replaced (generally three times).
17. Check if the filter screen of the lubrication system is clogged. If it is, it needs to be cleaned.
18. Unscrew the screw plug on the drain flange to discharge the dirt and water accumulated in the oil pool.
19. Check whether the bolts and nuts at the hydraulic end are loose or damaged. If so, tighten them as per the regulations or replace them.
20. Check the sealing ring inside the sealed box. If it is worn out, replace it. Replace it at least once every three months.
21. Check if the filter cartridge at the discharge outlet is clogged. If it is, it needs to be cleaned.
22. Replace the dirty oil in the power end oil pool and the crosshead sedimentation oil tank every six months and clean them thoroughly.
23. Check the wear condition of the crosshead and guide plate surfaces. If necessary, rotate the crosshead 180° before using it again.
24. Check if the guide plate is loose and if the crosshead clearance meets the requirements. If so, conduct an inspection and adjustment.
25. Check the wear of the gear pair and adjust the surface for use if necessary.
26. Check the wear of the gear pair and adjust the surface for use if necessary.
27. Check whether there is any damage to the bearings at the power end. If any damage is found, they need to be replaced.
28. Check the sealing of the rear cover, crankshaft end cover and other parts. If they fail to achieve a good sealing effect, they should be replaced.
II. Maintenance and Care Precautions:
1.Before clamping the upper intermediate rod with the piston rod, the conical surfaces of the mating parts must be wiped clean.
2.When changing the cylinder liner. The cylinder liner sealing ring must be replaced together.
3. After the pump stops in winter. Or the pump is temporarily shut down for more than 10 days. The drilling fluid in the valve cavity and cylinder liner must be drained completely and flushed clean.
4. All inspection window holes should be properly covered. To prevent sand and dust from mixing into the lubricating oil.
5.The air discharge bag can only be filled with nitrogen or air. It is strictly prohibited to fill it with flammable or explosive gases such as oxygen or hydrogen.