Analysis Of The Functions Of Each Instrument In The Hydraulic Choke Manifold Control Panel

Oct 30, 2025 Leave a message

1.Standpipe pressure gauge

Core function: It monitors the pressure of the fluid pumped into the wellbore by the drilling pump, serving as the core calculation benchmark and process monitoring parameter for well-killing operations.

This gauge is connected to the high-pressure manifold at the outlet of the drilling pump.

Under shut-in conditions: The "initial shut-in standpipe pressure" read is the most crucial data for calculating formation pressure, the required density of drilling fluid for well control, and pump speed. It directly reflects the difference between the bottom hole pressure and the static pressure of the drilling fluid column in the wellbore.

Under the well control circulation condition: The operator must follow the well control construction plan and control the choke valve to make the standpipe pressure change along the predetermined "well control circulation standpipe pressure curve" (for example, maintaining the initial standpipe pressure unchanged during the first circulation cycle of the driller method), in order to ensure that the pressure applied to the bottom of the well is constant and safe. It is the primary parameter that is continuously and closely monitored during the well control process.

Summary: It is the core instrument that indicates "how much pressure needs to be applied to control the well".

 

2.Casing pressure gauge

Core function: Directly displays the pressure of the annular space (casing) at the wellhead, which is a key monitoring parameter for preventing wellbore collapse and ensuring wellhead safety.

This gauge is connected to the annular outlet of the casing head at the top of the wellhead device or the annular space of the blowout preventer assembly.

In the well shut-in condition: "The shut-in casing pressure" directly shows the pressure formed after the formation fluids invade the annular space of the wellbore. This pressure must be strictly controlled within a safe range, and its upper limit depends on the minimum value among the rated working pressure of the wellhead equipment, the casing's internal pressure resistance strength, and the formation's fracture pressure.

Under the well control circulation condition: In the "driller's method" and other well control techniques, the core operation is to finely adjust the choke valve to stabilize the well pressure at the initial shut-in well pressure value, until the heavy drilling fluid reaches the bottom of the well.

Summary: It acts as a "sentinel" for the wellhead and the formation, ensuring that the pressure does not get out of control and result in blowouts or pressure leaks in the formation.

 

3.Hydraulic oil pressure gauge

Core function: Displays the driving power source of the hydraulic throttle valve - the working pressure of the hydraulic system.

This gauge measures the main system oil pressure output by the hydraulic pump in the control box. This pressure must be stable within the range specified by the manufacturer (such as 10.5 MPa to 14 MPa) in order to provide sufficient and stable driving force for the hydraulic throttle valve.

The stability of the oil pressure is a prerequisite for the throttle valve to respond sensitively and precisely to the control instructions. If the oil pressure is too low or fluctuates violently, the throttle valve will operate slowly or get stuck, which is extremely dangerous in emergency well control situations.

Summary: It is the "heart monitor" of the control panel, indicating whether the power system is in good condition and functioning effectively.

 

4.Pressure gauge of the pressure regulating valve

Core function: Displays the command pressure set by the operator, which is used to control the opening degree of the throttle valve.

This is the key instrument for achieving precise control. The operator rotates the handwheel of the pressure regulating valve on the control box to set a control pressure (leading pressure).

This pressure gauge shows exactly this commanded pressure, which is proportional to the opening degree of the throttle valve. It does not directly represent the system oil pressure, but rather represents the operator's control intention.

The operator adjusts the opening degree of the throttle valve (by regulating the pressure regulating valve and observing the reading on this gauge) based on changes in the standpipe pressure and casing pressure, thereby achieving fine adjustment of the well pressure.

Summary: It is the operator's "throttle gauge", and the readings on the gauge directly correspond to the opening degree of the throttle valve.

 

5.Air source pressure gauge

Core function: Monitor the pressure of the compressed air source that drives the pneumatic hydraulic pump.

For control boxes that use pneumatic pumps as the hydraulic source, this table is of crucial importance. It shows the compressed air pressure from the drilling air system.

The air source pressure must be stable at the required value (such as 0.6 - 0.8 MPa) to ensure the normal operation of the pneumatic hydraulic pump and thereby generate stable hydraulic oil pressure. Insufficient air source pressure will directly lead to the failure of the entire hydraulic system.

Summary: It serves as the "power source indicator" of the entire control system, just like the water inlet gate of a power plant.

 

6.Oil and gas separator pressure gauge

Core Function: Monitors the pressure of the oil separator in the hydraulic oil tank to determine whether the suction port of the hydraulic pump is unobstructed and to prevent cavitation.

This is a maintenance-oriented instrument that is often overlooked but is extremely important. When the hydraulic pump is operating, it will stir the hydraulic oil, causing positive or negative pressure within the oil tank.

The function of the oil-gas separator (breather) is to maintain the internal pressure of the oil tank in balance with the atmospheric pressure, prevent dust from entering, and allow the oil and gas to be discharged.

This pressure gauge is usually connected to the top of the oil tank or the separator. If the gauge shows an excessively high positive pressure, it indicates that the filter screen of the separator may be clogged and should be cleaned in time; otherwise, it will increase the load on the pump. If it shows negative pressure, it indicates that the suction valve is faulty or clogged, which will cause the hydraulic pump to have difficulty in drawing oil and result in cavitation, damaging the pump body.

Summary: It serves as an indicator for the "breathing health" of the hydraulic system, used to provide early warnings of potential maintenance issues.

 

Summary and Linkage Relationship

These instruments form a well-structured monitoring system:

The well condition perception layer (object): The standpipe pressure gauge and the casing pressure gauge directly reflect the wellbore status and are the targets and basis for operation.

The command control layer (means): The pressure gauge of the regulating valve is a quantitative manifestation of the control instructions issued by the operator.

The power support layer (foundation): The gas source pressure gauge, the oil pressure gauge, and the pressure gauge of the oil-gas separator jointly ensure that the power system (hydraulic system) for executing the instructions is in a healthy state.

 

During the well control operation, the operator needs to continuously monitor the changes in standpipe pressure and casing pressure. By adjusting the pressure regulating valve (and observing the pressure gauge of the regulating valve), they should control the choke valve. At the same time, they must keep an eye on the gas source pressure, oil pressure and the pressure of the oil-gas separator to ensure that the control system is working properly. Any abnormal reading of an instrument must be dealt with immediately. Please always refer to the latest version of the "Operation and Maintenance Manual" for the equipment as the final reference.